Series No. 892

Features:

  • CSA/CUR/TUV/VDE Approved
  • High Insulation System Approval
  • High Electrical Noise Immunity
  • High Switching Capacity in a Compact Package
  • High Senstivity: 200mW and 400mW
  • High Surge Voltage: 3,000V between Contacts and Coil

Drawing/Terminal layout:

892.gif

Relay photograph:

t892w.jpg







p>

DESCRIPTION DETAILS DESCRIPTION DETAILS
Size(LxWxH) not including terminals 20.0x10.0x16.0 Contact Configuration 1 FORM C
Max.Allowable Contact current 7A Contact Rating Resistive load 7A/240VAC
10A/120VAC
Insulation System None Coil Voltage DC: 6-24VDC
Coil Operating Power at nominal voltage DC: 1.1Wx2 Expected mechanical life(min.) 1x10^7
Expected electrical life (min.) 1x10^5 Terminal type General Purpose Relays
Dielectric Strength AC Voltage- 1 minute
Between open contact 1000V Between contact and coil 4000V
Between contact circuits      
Datasheet
Download this file (892.pdf)892 Relay339 kB